What routine maintenance do you recommend when the switch box is removed from the kiln?

There are two basic parts of a kiln: the firing chamber and the switch box. (If your kiln doesn’t have a switch box, it is probably because the electrical parts are kept inside the enclosed base of the kiln. An example is the Paragon SC-2 silver clay kiln.)

When you need to remove the switch box, such as when you change elements, it is a good idea to perform the following maintenance steps. You might also do this after purchasing a used kiln.

However, these maintenance steps are usually unnecessary for the small tabletop kilns such as the SC-2. The small jewelry kilns operate on only 120 volts, fire to relatively low temperatures, and are usually subjected to less dust than the larger studio kilns.

SWITCH BOX MAINTENANCE

1) Always disconnect the power. Then remove the switch box following the instructions in your kiln manual. If your switch box has a Kiln Sitter, pull straight out to avoid damaging the Kiln Sitter tube.

2) Unless your switch box is hinged, find something to prop it up so that it doesn’t pull against the element wires. Position the switch box so that you can see inside it easily.

3) Dust can cause parts to overheat, because dust acts as an insulator. After changing the elements or thermocouple, blow dust out of the switch box using canned air. (It is available from computer or camera stores or even Wal-Mart.) Wear a facemask. Do not hold the canned air upside down, and never spray yourself. (The air gets cold enough to cause injury.) Hold the air nozzle 6” away from the parts you are spraying.

You could also use a vacuum cleaner and a dry paintbrush to clean the switch box of switch-operated kilns. But we do not recommend them for cleaning digital kilns. They can create a static charge that could damage the electronic controller.

4) Examine the wires. Use a flashlight if lighting around the kiln is dim. After decades of heat, the insulation on wires becomes brittle. Signs of aging insulation are white wires that are brownish and colored wires that are fading. When you bend wires, do you hear or feel the insulation cracking? When insulation cracks off the wires, it is also likely that strands of wire are breaking, too, which can raise the resistance and cause the wires to overheat. Replace damaged wires. Make sure the terminals are tight when installing new wires.

Do not use electrical tape to repair wiring inside a kiln switch box.

5) After cleaning the switch box and checking the wires for heat damage, then check the wire terminals for tightness. If terminals seem corroded, but everything is working, I would not clean the terminals. I would leave well enough alone. (On the other hand, if a switch has stopped working, sometimes just cleaning the terminals can get it working again.)



Paragon Kilns on FacebookParagon Kilns on Twitter Paragon Kilns on YouTube Paragon RSS Feed

Kilns Sold

Get The Adobe Reader

Home

  • Home
  • Privacy Statement
  • Legal Notice
  • Paragon's Green Statement
  • Where To Buy Kilns
  • Resellers
  • About Us
  • Contact Paragon
  • News & Events
  • Support

  • Kiln Technicians
  • Kiln Support
  • Products

  • Bead Kiln
  • Glass Blower's Crucible Furnace
  • Ceramic Kilns
  • China Painting Kilns
  • Enameling Kilns
  • Industrial Furnaces
  • Glass Kilns
  • Lamp Working Kilns
  • Pottery/Ceramic and Glass
  • Pottery Kilns
  • Silver Clay Kilns
  • Wax Burnout Furnaces
  • Heat Treating Furnaces
  • Knife Making Furnaces
  • Custom Furnaces
  • Discontinued Models
  • “Custom and standard Kilns and Industrial Furnaces for ceramics, pottery, heat treating, enameling,
    dentistry, laboratory, and glass fusing.
    Better Designed Kilns from Paragon Industries!"